Skip to content
PAP Group, part of ProseroPAP Group, part of Prosero
Search the site

Suggested searches

Quick links

Request a quote
MenuClose
Panasonic 2842 intrinsically safe isolator unit

Panasonic

Panasonic 2842 intrinsically safe isolator unit

Product code 41577

Intrinsically safe isolator unit for connecting the 2840 and 2841 addressable IS detectors to the COM loop of a Panasonic fire alarm control panel. Installed outside the Ex area.

  • Connects up to 20 IS detectors (2840/2841) to the COM loop
  • IS COM line up to 500 m, no return conductor or end-of-line resistor
  • IP66/67 enclosure, five cable glands included
  • Approved to EN 54-18, ATEX II (1) G [Ex ia Ga] IIC
  • No address or programming required

The product sheet opens in a new tab, where you can print or save it.

A quote or help choosing products? Sales+358 40 668 7641myynti@pap.fi

A technical question about a device? Technical support+358 40 668 7643tuki@pap.fi

Product description

Panasonic 2842 is an intrinsically safe (IS) isolator unit through which the 2840 addressable IS smoke detectors and 2841 IS heat detectors are connected to the COM loop of the fire alarm control panel. The isolator unit is installed outside the hazardous area, and an IS COM line runs from it into the Ex area. One or more isolator units can be connected to the same COM loop, together with other EBL system loop devices.

Up to 20 IS detectors can be connected to the IS COM line. The line is a simple radial cable without a return conductor or end-of-line resistor, and it can be up to 500 m long. The COM loop is isolated from the IS COM line by an optocoupler, and the unit’s 24 V supply is isolated from the IS line by a DC/DC converter that limits the power fed into the Ex area. The nominal voltage of the IS COM line is 16 V DC. The isolator unit requires no address or programming.

Installation

The unit is wall-mounted outside the Ex area in a waterproof IP66/67 enclosure, supplied with five cable glands and four fixings. The connections are COM loop in and out, external 24 V DC supply (50 mA) in and out, and a blue IS COM terminal. A suitable IS COM cable is, for example, FKAR-PG 2 × 0.5 mm² (blue), and it must be routed separately from other cables.

Technical data

Product code
41577
Manufacturer
Panasonic
Product group
Fire alarm systems › Field devices › Ex detectors
Weight
3100 g
Dimensions
300 × 300 × 132 mm
IP rating
IP66/67
Operating temperature
−10…+55 °C
Operating voltage
24 V DC (12–30 V DC), external supply
EN 54 approval
EN 54-18
ATEX certificate
DEKRA 11ATEX0106
CPR
0786-CPR-21785
Material
Flame-retardant ABS and polycarbonate
Colour
Grey
Storage temperature
−25…+70 °C
Humidity
Max. 95% RH, non-condensing
Current consumption (quiescent)
≤ 10 mA
Current consumption (alarm)
≤ 50 mA
Capacity
Max. 20 IS detectors, IS COM line max. 500 m
ATEX zone
Safe area (not a hazardous area)
ATEX classification
II (1) G [Ex ia Ga] IIC
Mounting
Wall mounting outside the hazardous area

Documents

Original manufacturer documents (PDF).

Certificates and declarations

More products in this product group

Need help choosing products?

Our sales team will help you choose devices that suit the site and the existing system, and will prepare a quotation. Tell us about the system, the site and the quantities needed.

Contact sales +358 40 668 7641