Panasonic 4433FI addressable manual call point

Panasonic

Panasonic 4433FI addressable manual call point

Product code 41380

Addressable manual call point with a built-in short-circuit isolator for Panasonic fire alarm systems. Intended for dry indoor premises for immediate manual activation of a fire alarm.

  • Addressable, connected directly to the COM loop
  • Built-in short-circuit isolator
  • Approved to EN 54-11 and EN 54-17, VdS G 213004
  • Transparent protective flap prevents accidental activation
  • Automatic addressing with EBLWin or with an address setting tool
  • Testing with a test key without breaking the glass element

The product sheet opens in a new tab, where you can print or save it.

A quote or help choosing products? Sales+358 40 668 7641myynti@pap.fi

A technical question about a device? Technical support+358 40 668 7643tuki@pap.fi

Product description

Panasonic 4433 is an addressable manual call point with a built-in short-circuit isolator. A fire alarm is raised manually by pressing the glass element until it breaks, and the fire alarm control panel then receives a fire alarm. The call point is intended for indoor use in dry premises; for damp premises and outdoors, the enclosed IP66 model 4439 is suitable.

Accidental activation is prevented by a transparent polycarbonate protective flap, which must be lifted before the glass element is pressed. The call point indicator flashes to show communication with the control panel (flashing can be disabled in EBLWin) and is lit continuously when the call point has triggered an alarm. Periodic testing is carried out with a test key: when the key is inserted into the hole in the front cover, the call point operates as if activated, and after the key is removed the alarm is reset at the control panel.

Installation

The call point is mounted on the wall in a red back box prepared for cable entry from the rear. For surface mounting, cable entries can be drilled in the top or bottom of the back box (max. Ø 20 mm). The connection conductor size is 0.5–2 mm².

Every device on the COM loop must have a unique address (001–253). The address can be set automatically with EBLWin or manually with address setting tool 4414/4414E before the device is connected to the loop. The call point works with EBL512 G3, EBLOne and EBL128 control panels; the short-circuit isolator is in use in NORMAL mode.

Technical data

Product code
41380
Manufacturer
Panasonic
Product group
Fire alarm systems › Field devices › Manual call points
Weight
201 g
Dimensions
87 × 87 × 60 mm (H × W × D)
Operating temperature
−10…+55 °C
EN 54 approval
EN 54-11, EN 54-17
VdS approval
G 213004
CPR
0786-CPR-21235
Storage temperature
−40…+85 °C
Humidity
Max. 90% RH, non-condensing
IP rating
IP42
Colour
Red (ISO 3864)
Material
Flame-retardant ABS and polycarbonate
Operating voltage
12–30 V DC (nominal 24 V DC)
Current consumption (quiescent)
1.6 mA
Current consumption (alarm)
2.7 mA
Address range
001–253
Short-circuit isolator
Yes
Operating mode
Direct operation, type A
Mounting
Wall mounting, indoors
Connection
Conductor 0.5–2 mm² (Ø 0.8–1.6 mm)
Standards
VdS 2344, VdS 2504, EN 61000-6-3, EN 50130-4, EN IEC 63000

Documents

Original manufacturer documents (PDF).

Technical datasheets

Certificates and declarations

More products in this product group

Need help choosing products?

Our sales team will help you choose devices that suit the site and the existing system, and will prepare a quotation. Tell us about the system, the site and the quantities needed.

Contact sales +358 40 668 7641